TYPE OF BATTERIES |
Part Number |
PS-TL-90 |
PS-TL-36
|
PS-TL-54 |
PS-TL-INT |
Battery Hour |
300W, 90 Amp-hour Battery and 3 Outlets |
300W, 36 Amp-hour Battery and 3 Outlets |
300W , 54 Amp-hour Battery and 3 Outlets |
230V, 300W, 90 Amp-hour Battery and 1 C13 Outlet
|
Intended Application |
Hospitals & Medical Facilities |
Hospitals & Medical Facilities |
Hospitals & Medical Facilities |
Hospitals & Medical Facilities |
|
|
|
|
|
OUTPUT |
Frequency compatiblity |
60 Hz |
60 Hz |
60 Hz |
50 HZ |
Output watts |
300 |
300 |
300 |
300 |
Coninuous output capacity (wats) |
300 |
300 |
300 |
300 |
Peak output capacity (watts) |
750 |
750 |
750 |
750 |
Outptu nominal voltage |
120V |
120V |
120v |
230V |
Outlet quantity/type |
3 AC outlets |
3 AC outlets |
3 AC outlets |
1 IEC-320-C13 |
|
|
|
|
|
INPUT |
Recommended Electrical Service |
15A 120V |
15A, 120V |
15A, 120V |
15A, 230V |
Input connection type |
NEMA5-15p-hg Hospital-Grade |
NEMA 5-15P-HG Hospital-Grade |
NEMA 5-15P-HG Hospital-Grade |
IEC-320-C14 |
Input cord length (ft.) |
10 |
10 |
10 |
order separately |
Input cord lenth (m) |
3.05 |
3.05 |
3.05 |
11 |
Voltage compatiblitity(VAC) |
120 |
120 |
120 |
230 |
|
|
|
|
|
BATTERY |
DC system voltage (VDC) |
12 |
12 |
12 |
12 |
Full load runtime |
Up to 12 hours typical runtime in standard configuration.
click to above
|
click to above |
click to above |
Up to 12 hours typical runtime in standard configuration.
click to above |
Battery recharge rate |
Equal to discharge time. Includes advanced 3-stage (10A) battery chargerd |
Equal to discharge time. Includes advanced 3-stage (10A) battery charger |
Equal to discharge time. Includes advanced 3-stage (10A) battery charger |
Equal to discharge time. Includes advanced 3-stage (10A) battery charger |
|
|
|
|
|
LEDS ALARMS & SWITCHES |
Alarms |
Low Battery Alarm |
Low Battery Alarm |
Low Battery Alarm |
Low Battery Alarm |
Switches |
On Remote User Interface (RUI): On/Off Switch and Alarm-Mute Switch |
On Remote User Interface (RUI): On/Off Switch and Alarm-Mute Switch |
On Remote User Interface (RUI): On/Off Switch and Alarm-Mute Switch |
On Remote User Interface (RUI): On/Off Switch and Alarm-Mute Switch |
Front panel LEDs |
On Remote User Interface (RUI): Output AC Power, Battery Charge Level and Battery Charging Status |
On Remote User Interface (RUI): Output AC Power, Battery Charge Level and Battery Charging Status |
On Remote User Interface (RUI): Output AC Power, Battery Charge Level and Battery Charging Status |
On Remote User Interface (RUI): Output AC Power, Battery Charge Level and Battery Charging Status |
|
|
|
|
|
SURGE/NOISE SUPPRESSION |
EMI / RFI AC noise suppression |
Yes |
Yes |
Yes |
Yes |
|
|
|
|
|
PHYSICAL |
Shipping weight (lbs) |
104 |
72.4 |
88 |
Power Supply: 16 lb. Battery Module: 67.1 lb. |
Cooling method |
Fan |
Fan |
Fan |
fan |
Material of construction |
Power Supply and Battery Module: metal |
Power Supply and Battery Module: metal |
Power Supply and Battery Module: metal |
Power Supply and Battery Module: metal |
Style |
Heavy-duty with built-in battery charger |
Heavy-duty with built-in battery charger |
Heavy-duty with built-in battery charger |
Heavy-duty with built-in battery charger |
|
|
|
|
|
COMMUNICATIONS |
Network monitoring port |
USB |
USB |
USB |
USB |
Software and cabling included |
PowerAlert Data-Saving Software CD and USB cable |
PowerAlert Data-Saving Software CD and USB cable |
PowerAlert Data-Saving Software CD and USB cable |
PowerAlert Data-Saving Software CD and USB cable |
|
|
|
|
|
SPECIAL FEATURES |
Remote control capability |
Yes |
Yes |
Yes |
Yes |
|
|
|
|
|
CERTIFICATIONS |
Certifications |
Tested, certified and compliant to UL 60601-1, CAN/CSA-C22.2 No. 601.1-M90 and UL 1778 by TUV |
Tested, certified and compliant to UL 60601-1, CAN/CSA-C22.2 No. 601.1-M90 and UL 1778 by TUV |
Tested, certified and compliant to UL 60601-1, CAN/CSA-C22.2 No. 601.1-M90 and UL 1778 by TUV |
Tested certified and compliant to IEC 60601-1, CAN/CSA-C22.2 No. 601.1-M90 and UL 1778 by TUV |